Mitsubishi Ecodan Servicing & Repair

Annual servicing, fault diagnosis and running-cost optimisation for Mitsubishi Electric Ecodan air source heat pumps across Orpington, Bromley, Sevenoaks and Kent. £170 with no VAT.

verified_userASHP Level 3 Qualified
savingsRunning-Cost Optimisation
descriptionWritten Report Every Visit

paymentsEcodan Servicing

  • check_circle£170 full annual service, no VAT
  • check_circle£270 Ecodan + cylinder together
  • check_circleFTC controller settings reviewed
  • check_circleWritten performance report
  • check_circleAny installer, warranty checked
buildEcodan Specifics

What I Check on an Ecodan

The Ecodan is one of the most common heat pumps in this part of Kent and South East London, and it is a genuinely good unit. Almost every complaint I get about one turns out to be commissioning rather than the equipment.

The FTC controller settings

This is where the money is. Ecodan systems run Auto Adaptation and weather compensation through the FTC, and I regularly find them disabled with a fixed flow temperature set at 50°C or higher — because it warms the house fast on handover day. The same property will usually run happily at 40–45°C and use noticeably less electricity.

System pressure and expansion vessel

Ecodan installations are sensitive to a poorly charged expansion vessel. Pressure swings, the relief valve passes, you top up, and every top-up introduces oxygenated water that causes sludge and eventually blocks the plate heat exchanger.

Glycol and freeze protection

Checked properly, not eyeballed. Weak concentration risks frozen external pipework in a hard winter, particularly on the more exposed rural installations around Sevenoaks and the Kent villages.

Strainer, pump and flow rate

A partially blocked strainer quietly starves the system of flow, which the Ecodan then compensates for by working harder. Cleaning it is routine and it is skipped constantly.

Cylinder coil and legionella cycle

On Ecodan systems paired with a cylinder I check the coil performance and that the legionella cycle is set sensibly — not so often it wastes electricity, not so rarely it becomes a safety issue.

helpFAQ

Mitsubishi Ecodan Questions

Yes. I'm ASHP Level 3 qualified and service Ecodan systems across Orpington, Bromley, Sevenoaks and Kent — regardless of who originally installed them.
£170 with no VAT for a full annual service including a written report. Combined with an unvented cylinder service in the same visit it is £270, saving £40.
In nearly every case it is the settings, not the hardware. Ecodan units have Auto Adaptation and weather compensation built in, and I regularly find both switched off with a fixed flow temperature set high. Turning that around is an optimisation visit, not a repair.
Ecodan uses a letter-and-number fault code on the FTC controller. Codes in the L series usually point to flow or pressure problems, P series to sensor or thermistor faults. I'd rather read the code on site with the system running than guess over the phone.
Yes, and it is a common request from 2021 to 2023 grant-era installations. I check the warranty terms first so servicing keeps your manufacturer cover intact.
I explain what I am changing and why first. They are your bills. If you would rather I left something alone, I note that in the report.
Yes, and it is arguably the better time — you are not without heating if something needs ordering, and my diary is easier.
Often more so. Grant-era installations are exactly where I find fixed high flow temperatures and weather compensation switched off from day one.
Yes, plainly. I would rather find nothing and say so than invent a problem to justify the visit.
Annually. It is what manufacturers require for warranty, and it is when settings drift and small problems get caught.

Book Your Ecodan Service

£170 with no VAT, written report every visit, across Orpington, Bromley, Sevenoaks and Kent.

call07717 846247
Warning Signs

When to Get It Checked

Very few heat pumps fail suddenly. They drift, quietly, and the bill is usually the first thing anyone notices.

Fault codes appearing and clearing themselves

Intermittent codes are worth noting rather than dismissing. They usually precede a hard fault by weeks or months.

Short cycling on and off

The unit is producing more heat than the system can absorb — usually flow temperature too high or flow rate restricted. It wears the compressor and wastes electricity.

It runs constantly in mild weather

Should be modulating down, not running flat out in October. Usually a compensation curve issue or a controls setting.

Pressure dropping, needing top-ups

Points at an expansion vessel that has lost its charge. Every top-up brings in oxygenated water, which becomes sludge, which blocks the plate heat exchanger.

Ice that does not clear after a defrost

Defrost cycles look alarming the first winter and are normal. Ice that persists afterwards is not, and wants looking at before it causes damage.

Costs

Prices and What You Get

Most heat pump problems I attend need no parts at all, because they turn out to be settings rather than failures. Where parts are needed I quote a fixed price before ordering.

A full annual service is £170 with no VAT. Not VAT-registered, so that is the complete figure.

An optimisation visit includes before and after readings in writing. If the numbers do not improve I will tell you that, rather than claiming a saving I cannot evidence.

Air source heat pump fan and condenser coil inspected during service
Fan blade and condenser coil exposed for inspection during a heat pump service. Illustrative of the work; unit pictured is not an Ecodan
callCall Gary — 07717 846247